Heavy Duty Turbine Electric Fans are suitable for most primary and auxiliary cooling applications found on many cars, trucks, buses, etc. A complete selection of heavy duty 12 and 24 volt models ranging in size up to 30" diameter as well as custom designed units are available for many types of heat exchanger applications including radiator, A/C condenser, charged air engine oil, hydraulic oil, transmission oil, etc. They are fully reversible (will push or pull air), allowing them to be installed in front of or behind the radiator or heat exchanger. Complete systems that will replace most conventional belt-driven or factory-installed electric fans are available. No other electric fans cover more applications, provide more air flow, come in larger diameters, or have a better mounting system.
Note: Units are not suitable to operate in explosive environments or aviation applications.
- Improves fuel economy (up to 15%) and performance
- operates off batteries – not engine horsepower.
- Reduces maintenance costs because it is thermostatically controlled and operates only when necessary. Other types of on-off fans are constantly turning, wearing out internal components of the fan hub.
- Field proven since 1980.
- Can meet most OEM applications.
- Increases vehicle output by eliminating the large horsepower requirements of belt-driven on-off fans.
- Provides better control of engine temperature – increasing motor life.
- Increases belt and water pump life.
- In most cases, costs less to install and maintain.
- Reduces vibration and noise since it is not attached to the motor.
- Eliminates fan alignment problems on vehicles, allowing greater flexibility in the design of cooling systems
- Allows easier access to front-mounted engine accessories.
- Universal – will fit many vehicles, reducing costly inventories.
- Provides better cooling at idle.
- Does not require lubrication.
- Reversible – will push or pull air.
- Does not require an air source for fan engagement.
- Easily mounts, using our telescopic or flat steel mounting hardware.
- Can be used for auxiliary cooling.
- Allows heat exchangers to be easily relocated.
|
|
Turbine Fans for Automobiles and Pick-up Trucks

APPLICATIONS
(For automotive applications that benefit from Ram Air Cooling)
|
|
Model #
|
Volts
|
Amps
|
CFM (1)
|
Dia.
|
Assembled
Depth
|
For Engines
Under
|
|
2000-8
|
12 (3)
|
3
|
200
|
8"
|
2.5"
|
Auxiliary Cooling
|
|
2000-10
|
12 (3)
|
10
|
1100
|
10"
|
3.25"
|
Auxiliary Cooling
|
|
2000-12
|
12 (3)
|
12
|
1500
|
12"
|
3.25"
|
150 C.I.
|
|
2000-16
|
12 (3)
|
14
|
2000
|
16"
|
4"
|
200 C.I.
|
|
4000-18 (2)
|
12 (3)
|
12
|
2000
|
18"
|
7"
|
327 C.I.
|
|
3000-16 (2)
|
12
|
18
|
3000
|
16"
|
6"
|
350 C.I.
|
|
3000-21 (2)
|
12
|
20
|
4500
|
21"
|
6"
|
400 C.I.
|
(1) CFM at "0" static pressure.
(2) Fan blades may be reduced in diameter.
(3) Also availiable for 24 volt applications.
Note: Model 3000 has an open ventilated frame and is not recomended for harsh environments.
|
HIGH PERFORMANCE COOLING
Series 2000, 3000, and 4000 TURBINE ELECTIRC FANS are recommended for difficult cooling applications found on cars and pickup trucks. They are designed to out-perform other types of electric fans including original equipment. |
FEATURES
- Permanent magnet
- Totally enclosed (model 3000 open)
- Duty cycle - continuous air over
- Fan diameter to 24"
- CFM Ratings to 4500
- Structurally mounts to the radiator frame
|
|
|
Turbine Electric Fans for Over-the-road Trucks
A Unique System for Diesel Engine Cooling
Most over-the-road vehicles that benefit from ram air cooling (air forced through the radiator by the vehicle's motion) may use the Series 3000, 5500, 6000, or 6500 Turbine Electric Fans to replace their conventional belt-driven fans.
| FEATURES |
- 4 Pole Construction
- Models availiable for 12 and 24 Volt Applications
- Permanent Magnet
- Totally Enclosed (Model 3000 open)
- Telescopic Mounting
- Optional Weatherproofing
- Bi-Rotational (Will push or pull air)
- Fan Blades made of Polypropylene or Delrin.
May be reduced in size by the purchaser
- Duty Cycle - continuous air over
- Fan Diameters - up to 29"
- CFM Ratings up to 10125
- Motor Output up to 1.25 HP
- Easy Brush access (Not availiable on Model 3000)
|
|
 |

TWO SYSTEMS TO CHOOSE FROM
EFE can supply single or low profile dual fan assemblies. Single fan assemblies are recommended for difficult cooling applications that require the maximum amount of air flow. They are quickly installed since only one unit is required.
|
|
EASY INSTALLATION
Most kits are fully assembled (Series 6000 and 6500 are semi-assembled) and contain fan blade, motor, steel fan shroud, and may be easily attached to the frame of the radiator by utilizing our unique telescopic mounting hardware. |
|
SPECIFICATIONS
|
|
Model #
|
A Shroud
Diameter
|
Volts
|
Maximum
Amps
|
Maximum
CFM (2)
|
B
|
C
|
D
|
E (3)
Closed
|
E (3)
Open
|
Weight
Lbs.
|
|
3000-15JT (4)
|
16.50"
|
12
|
18
|
3000
|
3"
|
6.75"
|
6.5"
|
25"
|
40"
|
16
|
|
3000-21KT (4)
|
21.75"
|
12
|
20
|
4500
|
3"
|
6.75"
|
6.5"
|
25"
|
40"
|
18
|
|
3000-24MT (4)
|
24.75"
|
12
|
22
|
5000
|
3"
|
6.75"
|
6.5"
|
25"
|
40"
|
20
|
|
5500-21LT
|
21.75"
|
12 (1)
|
24
|
4500
|
3"
|
9.5"
|
4.8"
|
25"
|
40"
|
24
|
|
5500-24MT
|
24.75"
|
12 (1)
|
28
|
6000
|
3"
|
9.5"
|
4.8"
|
25"
|
40"
|
26
|
|
5500-26NT
|
26.00"
|
12 (1)
|
32
|
7400
|
3"
|
9.5"
|
4.8"
|
25"
|
40"
|
28
|
|
6000-21OT
|
21.75"
|
12 (1)
|
40
|
5500
|
3"
|
9.5"
|
6"
|
25"
|
40"
|
44
|
|
6000-24PT
|
24.75"
|
12 (1)
|
45
|
6300
|
3"
|
9.5"
|
6"
|
25"
|
40"
|
46
|
|
6000-26NT
|
26.00"
|
12 (1)
|
50
|
8000
|
3"
|
9.5"
|
6"
|
25"
|
40"
|
48
|
|
6500-21OT
|
21.75"
|
12 (1)
|
45
|
6200
|
3"
|
9.5"
|
8"
|
25"
|
40"
|
54
|
|
6500-24PT
|
24.75"
|
12 (1)
|
50
|
7000
|
3"
|
9.5"
|
8"
|
25"
|
40"
|
56
|
|
6500-26QT
|
26.00"
|
12 (1)
|
55
|
8800
|
3"
|
9.5"
|
8"
|
25"
|
40"
|
58
|
|
6500-28RT
|
28.00"
|
12 (1)
|
60
|
9000
|
|
10.5"
|
8"
|
25"
|
40"
|
65
|
|
6500-30ST
|
30.00"
|
12 (1)
|
70
|
10125
|
|
10.5"
|
8"
|
25"
|
40"
|
70
|
|
 |
(1) Also availiable for 24 volt applications. (3) For horizontal mounting only.
(4) Open construction - not recommended for (2) CFM at "0" Static Pressure
harsh enviroments. |
|
LOW PROFILE AND DUAL FAN APPLICATIONS CHART Patented*
|
Engine HP
Up To:
|
Gross Vehicle
Weight (Lbs.)
|
Minimum Radiator
Core Surface Area
Required for Installation
|
Minimum Clearance
Between Engine and
Radiator for Installation
|
Fan
Model
|
Fan
Shroud
Dia.
|
No. of
Fans
Required
|
|
250
|
under 40,000
|
34" x 18" 32" x 26"
|
7.5"
|
3000-15JT
|
17"
|
2
|
|
300
|
under 50,000
|
40" x 23" 38" x 27"
|
7.5"
|
3000-15JT
3000-21KT
|
17"
22"
|
1ea.
|
|
300
|
under 60,000
|
45" x 23" 44" x 28"
|
7.5"
|
3000-21KT
|
22"
|
2
|
|
350
|
under 60,000
|
39" x 28" 38" x 31"
|
10.5"
|
5500-21LT
3000-15JT
|
22"
17"
|
1ea.
|
|
350
|
under 80,000
|
45" x 23" 44" x 28"
|
10.5"
7.5"
|
5500-21LT
3000-21KT
|
22"
22"
|
1ea.
|
|
350
|
under 80,000
|
34" x 34"
|
7.5"
|
3000-15JTX
|
17"
|
4
|
|
400
|
under 80,000
|
45" x 23" 44" x 28"
|
10.5"
|
6000-21OT
|
22"
|
2
|
|
400
|
under 80,000
|
50" x 25" 48" x 34"
|
10.5"
|
6000-24PT
|
25"
|
2
|
|
SINGLE FAN APPLICATION CHART Patented
|
Engine HP
Up To:
|
Gross Vehicle
Weight (Lbs.)
|
Minimum Radiator
Core Surface Area
Required for Installation
|
Minimum Clearance
Between Engine and
Radiator for Installation
|
Fan
Model
|
Fan
Shroud
Dia.
|
No. of
Fans
Required
|
|
200
|
under 30,000
|
23" x 23"
|
7.5"
|
3000-21KT
|
22"
|
1
|
|
250
|
under 40,000
|
23" x 23"
|
10.5"
|
5500-21LT
|
22"
|
1
|
|
250
|
under 50,000
|
25" x 25"
|
10.5"
|
5500-24MT
|
25"
|
1
|
|
300
|
under 60,000
|
30" x 30"
|
10.5"
|
6000-26NT
|
26"
|
1
|
|
350
|
under 60,000
|
32" x 32"
|
10.5"
|
6000-26NT
|
26"
|
1
|
|
350
|
under 80,000
|
32" x 32"
|
10.5"
|
6500-26QT
|
26"
|
1
|
|
400
|
under 80,000
|
32" x 32"
|
11.5"
|
6500-28RT
|
28"
|
1
|
|
450
|
under 100,000
|
37" x 37"
|
11.5"
|
6500-30ST
|
30"
|
1
|
*Units may be installed diagonally across radiator core.
Series 3000-5500-6000-6500 models are also availiable without fan shroud
and telescopic mounting hardware.
Custom designed units are availiable if space limitations are encountered.
On some applications, it may be necessary to use more than the
recommended number of fans.
The above information is provided as a guide. The user assumes all
responsibility in the final selection and use of products.
|
|
|
|